The question this page answers Which systems and suppliers does a new, acquired or refitted dental practice in Canada outside Quebec have to choose, in what order, and which approvals have to be in place before the first patient?
On this page
This page is for you if you are opening a dental practice in Canada, buying one, or refitting one and changing systems. It covers practices outside Quebec. Our position: pick the practice management software first, and check it against the Canadian Dental Association’s list of certified software for CDAnet and ITRANS before you book a demo. Software Vendors (CDAnet and ITRANS Certified Vendors) | Canadian Dental Association (Canadian Dental Association (CDA))1 Claims to dental plans run through that system, and the scanner, the X-ray software and online booking all have to connect to it. Our practice management software comparison compares 4 verified suppliers on the same criteria, including CDAnet certification and where patient data is stored.
We give no legal or tax advice. Rules are described only where we have read the official text or the regulator’s own page, and the rules differ by province, so most of what follows names a province. Anything else is for you to check with your college, the regulators and your own advisers.
Where to start
The order below is a suggestion. It puts first the choices that are hardest to undo once the practice is open.
- Practice management software. Ask how claims are sent through CDAnet and ITRANS, CDAnet and ITRANS | Canadian Dental Association (Canadian Dental Association (CDA))2 whether your province’s fee guide is built in, and how you get every record out if you leave.
- X-ray, CBCT and the room. In Ontario, the X-ray installation needs written approval before it goes in (see below), so the X-ray plan belongs in the design of the premises, not after it. Our CBCT and X-ray comparison lists models with a named Canadian seller and a Health Canada device licence.
- Intraoral scanner. Our intraoral scanner comparison keeps the manufacturer, the model and the Canadian seller apart, so you can see who you are actually buying from.
- Consumables, materials and equipment. Our dental distributors page shows each distributor’s Health Canada establishment licence.
- Payments, booking and patient contact. Ask each tool whether it connects to the practice software from step 1, and where it keeps patient data.
When you buy an existing practice, ask the seller’s software vendor in writing how the records are exported and how long you can still read them after the contract ends. The purchase agreement does not answer that; the software contract does.
Approvals and rules we have read
X-ray equipment by province
Ontario: under the Healing Arts Radiation Protection Act, no one may install an X-ray machine without the Director’s written approval, and the owner may not use it on a person until the machine, its location and the owner’s name and business address are registered. Healing Arts Radiation Protection Act, R.S.O. 1990, c. H.2 (consolidated text) (Government of Ontario (e-Laws))3 The Royal College of Dental Surgeons of Ontario adds that the approval is also needed when an existing unit is replaced or the installation is changed. Information for dental x-ray facilities (Royal College of Dental Surgeons of Ontario (RCDSO))4 A dental CT scanner needs more: the facility must hold a permit from the College, which inspects before it issues one. CT Facility Permit (Royal College of Dental Surgeons of Ontario (RCDSO))5
Alberta: employers have to register radiation equipment through an authorized registration agency, Register your radiation equipment (Government of Alberta)6 and for diagnostic X-ray equipment in dental facilities that agency is the College of Dental Surgeons of Alberta, except in facilities owned by Alberta Health Services. Radiation agencies (Government of Alberta)7
British Columbia: WorkSafeBC’s occupational health and safety regulation requires ionizing radiation equipment to be installed, operated and maintained in line with listed codes, among them Health Canada’s Safety Code 30 for dentistry, and requires the employer to carry out a radiation survey. OHS Regulation Part 7: Noise, Vibration, Radiation and Temperature (WorkSafeBC)8 The BC Dental Association’s X-ray inspection program ended as a member service on May 31, 2025. Expectations for X-ray equipment inspections (British Columbia College of Oral Health Professionals (BCCOHP))9
We have not read the rules in the other provinces and territories.
Devices and who sells them
Before you sign for a chair, scanner or X-ray unit, check the seller’s role. Health Canada’s medical device establishment licence listing Medical Devices Establishment Licence (MDEL)Listing (Health Canada)10 says an MDEL is issued to Class I manufacturers and to importers or distributors of all device classes. If the seller imports or distributes the device in Canada, check whether it appears on that listing. We have not read Health Canada’s exemptions or its rules for other manufacturers, so a seller that is not listed is a question to put to Health Canada, not proof of a problem.
Patient data
Ask every vendor that stores patient data where it is stored and who can reach it, and get the answer in writing. We have not read Ontario’s Personal Health Information Protection Act, 2004 or any other province’s health privacy law: the e-Laws page did not return its text when we fetched it on 8 November 2026. Check the privacy rules for your practice with your regulator.
GST/HST on dental services
Under Part II of Schedule V to the Excise Tax Act, a health care service rendered to an individual by a medical practitioner is an exempt supply, and “medical practitioner” there includes a person entitled under provincial law to practise dentistry. Dental hygienist services are listed separately, and cosmetic services that are not for medical or reconstructive purposes are deemed not to be included. (Excise Tax Act, Schedule V, Part II, current to 19 October 2026, read 8 November 2026.) How that affects the GST/HST you pay on equipment and fit-out is a question for your accountant.
What this page does not cover
Quebec is outside this edition. We have not read official sources on dentist registration requirements in each province, incorporation, leases and zoning, payroll, building permits or provincial fee guides, so nothing is said about them here. We found no official figure for the cost of starting a dental practice in Canada (searched 7 November 2026); the premises, the build-out and the equipment are the large items, and only written quotes put a number on them.
Sources
Numbered by first appearance on the page. The date is when the source was last checked.
- Software Vendors (CDAnet and ITRANS Certified Vendors) | Canadian Dental Association, Canadian Dental Association (CDA). Checked October 24, 2026. Official sourceConfirmed in the source
- CDAnet and ITRANS | Canadian Dental Association, Canadian Dental Association (CDA). Checked October 24, 2026. Official sourceConfirmed in the source
- Healing Arts Radiation Protection Act, R.S.O. 1990, c. H.2 (consolidated text), Government of Ontario (e-Laws). Checked November 5, 2026. Official sourceConfirmed in the source
- Information for dental x-ray facilities, Royal College of Dental Surgeons of Ontario (RCDSO). Checked November 5, 2026. Official sourceConfirmed in the source
- CT Facility Permit, Royal College of Dental Surgeons of Ontario (RCDSO). Checked November 6, 2026. Official sourceConfirmed in the source
- Register your radiation equipment, Government of Alberta. Checked November 5, 2026. Official sourceConfirmed in the source
- Radiation agencies, Government of Alberta. Checked November 5, 2026. Official sourceConfirmed in the source
- OHS Regulation Part 7: Noise, Vibration, Radiation and Temperature, WorkSafeBC. Checked November 5, 2026. Official sourceConfirmed in the source
- Expectations for X-ray equipment inspections, British Columbia College of Oral Health Professionals (BCCOHP). Checked November 6, 2026. Official sourceConfirmed in the source
- Medical Devices Establishment Licence (MDEL)Listing, Health Canada. Checked November 5, 2026. Official sourceConfirmed in the source